- Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study
-
Hyunsuk Choi, Jae-Young Jo, Min-Ho Hong
-
J Yeungnam Med Sci. 2024;41(2):80-85. Published online January 22, 2024
-
DOI: https://doi.org/10.12701/jyms.2023.00934
-
Correction in: J Yeungnam Med Sci 2024;41(3):233
-
1,716
View
-
69
Download
-
1
Web of Science
-
Abstract
PDF
- Background
This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials.
Methods Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests ( α=0.05).
Results There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001).
Conclusion Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.
- A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report
-
Hyunsuk Choi, Sohee Kang
-
J Yeungnam Med Sci. 2022;39(4):341-343. Published online November 17, 2021
-
DOI: https://doi.org/10.12701/yujm.2021.01466
-
-
Abstract
PDF
- To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.
|