A study on evaluator factors affecting physician-patient interaction scores in clinical performance examinations: a single medical school experience
Young Soon Park, Kyung Hee Chun, Kyeong Soo Lee, Young Hwan Lee
Yeungnam Univ J Med. 2021;38(2):118-126.   Published online August 6, 2020
DOI: https://doi.org/10.12701/yujm.2020.00423
  • 5,585 View
  • 112 Download
  • 1 Crossref
AbstractAbstract PDF
Background
This study is an analysis of evaluator factors affecting physician-patient interaction (PPI) scores in clinical performance examination (CPX). The purpose of this study was to investigate possible ways to increase the reliability of the CPX evaluation.
Methods
The six-item Yeungnam University Scale (YUS), four-item analytic global rating scale (AGRS), and one-item holistic rating scale (HRS) were used to evaluate student performance in PPI. A total of 72 fourth-year students from Yeungnam University College of Medicine in Korea participated in the evaluation with 32 faculty and 16 standardized patient (SP) raters. The study then examined the differences in scores between types of scale, raters (SP vs. faculty), faculty specialty, evaluation experience, and level of fatigue as time passes.
Results
There were significant differences between faculty and SP scores in all three scales and a significant correlation among raters’ scores. Scores given by raters on items related to their specialty were lower than those given by raters on items out of their specialty. On the YUS and AGRS, there were significant differences based on the faculty’s evaluation experience; scores by raters who had three to ten previous evaluation experiences were lower than others’ scores. There were also significant differences among SP raters on all scales. The correlation between the YUS and AGRS/HRS declined significantly according to the length of evaluation time.
Conclusion
In CPX, PPI score reliability was found to be significantly affected by the evaluator factors as well as the type of scale.