Search
- Page Path
-
HOME
> Search
Review articles
- Surgery
- Current status of minimally invasive surgery for traumatic diaphragmatic injury: a narrative review
-
JongHyun Baek
, Jung-Min Bae
-
J Yeungnam Med Sci. 2026;43:72. Published online October 19, 2026
-
DOI: https://doi.org/10.12701/jyms.2026.43.72
-
-
Abstract
PDF
- Traumatic diaphragmatic injury (TDI) is a rare but life-threatening condition. Herniation of the abdominal organs through a traumatic diaphragmatic defect may progress to ischemia, perforation, and obstruction. The mortality rate associated with emergency surgery for TDI is 10% to 45%. In most cases, prompt repair is required once TDI has been confirmed. Computed tomography (CT) is the gold standard for diagnosing TDI. However, in situations with high clinical suspicion, the possibility of TDI cannot be definitively ruled out even if the CT scan is negative. Diagnostic laparoscopy and thoracoscopy are particularly useful when CT findings are equivocal and a diaphragmatic injury is suspected. The traditional emergency surgical approach to TDI is open surgery. Although minimally invasive approaches offer improved outcomes, traditional open approaches are still predominantly used. This is because the choice of minimally invasive surgery can be influenced by selection bias, varying trauma severity and complexity, and various practical obstacles. The four approaches (laparotomy, thoracotomy, laparoscopy, and thoracoscopy) have their own advantages and disadvantages. Therefore, it is important to select the approach that is best suited to the condition of each patient with TDI. Robotic surgery has been reported in four TDI cases, regardless of the literature search period. Notably, in one reported case, robotic surgery was performed as early as 2 days after the initial injury. In robotic emergency surgery for TDI, further studies are required to obtain significant clinical evidence.
- Thoracic and Cardiovascular Surgery
- Thoracic endovascular aortic repair in hyperacute type B aortic dissection: a mini review
-
JongHyun Baek
-
J Yeungnam Med Sci. 2026;43:70. Published online October 12, 2026
-
DOI: https://doi.org/10.12701/jyms.2026.43.70
-
-
Abstract
PDF
- Thoracic endovascular aortic repair (TEVAR) is established as the preferred treatment for many patients with complicated acute type B aortic dissection (TBAD). However, its role during the hyperacute phase (within 24 hours of symptom onset) remains controversial, as the acutely dissected aortic wall may be vulnerable to device-related injury. Nevertheless, hyperacute timing should not be regarded as an absolute contraindication to TEVAR. In patients with rupture, malperfusion, impending aortic rupture, persistent pain, refractory hypertension, or progressive true-lumen collapse, prompt entry-tear coverage can restore perfusion and prevent irreversible organ injury. Similarly, in patients without initial complications, high-risk anatomical features may help identify those who could benefit from early intervention. However, evidence supporting routine TEVAR within the first 24 hours remains limited and is predominantly observational. To ensure safe hyperacute TEVAR, careful assessment of the landing zones, conservative device sizing, avoidance of aggressive balloon molding, preservation of branch-vessel and spinal cord perfusion, and prompt recognition of retrograde type A dissection, stroke, spinal cord ischemia, and stent-graft-induced new entry are required. Ultimately, hyperacute TEVAR may be a reasonable option for selected patients with complicated TBAD, with a potential role in high-risk uncomplicated TBAD. Future prospective randomized trials integrating multimodal imaging and dynamic biomarkers are warranted to establish definitive criteria for timing and candidate selection.
Image vignette
- Thoracic and Cardiovascular Surgery
- Unveiling a rare ascending aortic limited intimal tear
-
JongHyun Baek
-
J Yeungnam Med Sci. 2026;43:65. Published online September 11, 2026
-
DOI: https://doi.org/10.12701/jyms.2026.43.65
-
-
PDF
Original article
- Thoracic and Cardiovascular Surgery
- Chest packing with negative pressure for refractory mediastinal bleeding after cardiac surgery: a low-cost, simple technique as an alternative to vacuum-assisted closure systems in a retrospective study
-
Hunbo Shim
, Seok Soo Lee
, Changseok Jeon
, Tae Hee Won
, Sang-Wan Ryu
, JongHyun Baek
-
J Yeungnam Med Sci. 2026;43:49. Published online July 27, 2026
-
DOI: https://doi.org/10.12701/jyms.2026.43.49
-
-
Abstract
PDF
- Background
Refractory mediastinal bleeding after cardiac surgery occasionally requires temporary open sternum and delayed sternal closure. We evaluated the feasibility and short‑term clinical performance of a modified chest‑gauze suction (c‑GSUC) technique that generates negative pressure using readily available materials.
Methods
We retrospectively reviewed 20 patients who underwent chest packing primarily for refractory bleeding following cardiac or thoracic aorta surgery. After routine drainage placement, gauze sponges were packed around the bleeding sites, and an additional temporary chest tube was positioned over the gauze. The open sternotomy was sealed with an adhesive drape and connected to a standard three-chamber drainage bottle to generate negative pressure and collapse the packed gauze.
Results
The median patient age was 57.0 years, and 19 patients (95.0%) underwent aorta-related procedures. Definitive chest closure was achieved within 2 days in 18 patients (90.0%). One patient (5.0%) required emergent washout for cardiac tamponade during open chest management. One patient (5.0%) developed mediastinitis after closure. Two patients (10.0%) died during hospitalization, one from septic shock and the other from intracranial hemorrhage.
Conclusion
Temporary open sternum with negative‑pressure gauze packing using the c‑GSUC technique was feasible in patients with refractory mediastinal bleeding and was associated with acceptable short‑term outcomes. Although less sophisticated than commercial vacuum-assisted closure systems, this simple and inexpensive approach may be a practical alternative in selected cases.
TOP