Skip Navigation
Skip to contents

JYMS : Journal of Yeungnam Medical Science

Indexed in: ESCI, Scopus, PubMed,
PubMed Central, Embase, CAS, KCI
FREE article processing charge
OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > J Yeungnam Med Sci > Volume 42; 2025 > Article
Original article
Urology
Improved patient comfort and procedural efficiency using chlorhexidine-coated hydrophilic urethral catheters: a randomized controlled trial
Seung-Kwon Choi1orcid, Jeonghyouk Choi2orcid, Dong-Gi Lee2orcid
Journal of Yeungnam Medical Science 2025;42:68.
DOI: https://doi.org/10.12701/jyms.2025.42.68
Published online: October 28, 2025

1Department of Urology, Seoul Medical Center, Seoul, Korea

2Department of Urology, Kyung Hee University College of Medicine, Seoul, Korea

Corresponding author: Seung-Kwon Choi, MD, PhD Department of Urology, Seoul Medical Center, 156 Sinnae-ro, Jungnang-gu, Seoul 02053, Korea Tel: +82-2-2276-7851 • Fax: +82-2-2276-7800 • E-mail: urocsk0127@hanmail.net, urocsk0127@seoulmc.or.kr
*Note: Clinical trial registration in the Clinical Research Information Service (CRIS) has been delayed due to service interruption following the recent fire at the National Information Resources Service in Korea. The registration number will be provided upon system restoration.
• Received: August 9, 2025   • Revised: October 5, 2025   • Accepted: October 27, 2025

© 2025 Yeungnam University College of Medicine, Yeungnam University Institute of Medical Science

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 2,477 Views
  • 79 Download
  • 1 Web of Science
  • 1 Crossref
  • Background
    This study aimed to evaluate the efficacy and convenience of a chlorhexidine-coated hydrophilic urethral catheter compared with a conventional silicone Foley catheter, focusing on patient discomfort, procedural time, and clinician satisfaction.
  • Methods
    This prospective randomized controlled study enrolled patients who required short-term urethral catheterization at two hospitals. The patients were randomly assigned to receive either a conventional urethral catheter (control group, n=64) or a chlorhexidine-coated hydrophilic urethral catheter (intervention group, n=67). The primary endpoints were patient-reported pain scores during catheter insertion and removal (pain scale, 0–10), procedural time (seconds), and clinician-reported satisfaction (0–10).
  • Results
    Patients in the intervention group reported significantly less pain during catheter insertion (mean score, 4.2 vs. 6.6; p<0.01) and removal (mean score, 2.8 vs. 4.5; p<0.01). The mean procedural time was shorter in the intervention group (215 seconds vs. 386 seconds; p<0.01), and clinician satisfaction was higher (mean score, 8.2 vs. 3.6; p<0.01). Patients in the intervention group were more likely to experience mild pain during catheter insertion (score, 0–3; 26.9% vs. 12.7%; odds ratio [OR], 2.53) and removal (score, 0–3; 83.6% vs. 42.9%; OR, 6.79). A greater proportion of procedures was completed within 150 seconds (59.7% vs. 44.4%; OR, 1.85), and clinicians reported higher satisfaction with the procedure (score, 8–10; 73.1% vs. 23.4%; OR, 8.71).
  • Conclusion
    Chlorhexidine-coated hydrophilic urethral catheters significantly reduced pain, shortened the procedural time, and improved clinician satisfaction. These findings suggest potential clinical benefits for both patients and clinicians.
Urethral catheterization, which includes perioperative management, acute urinary retention, and prolonged immobility, is a common and necessary procedure in urinary drainage. However, conventional silicone Foley catheters are often associated with significant patient discomfort, procedural inconvenience, and a high risk of catheter-associated urinary tract infections (CAUTIs) [1,2].
Several studies have reported that urethral catheter insertion can cause pain and anxiety in patients, especially men, due to frictional resistance and mechanical irritation of the urethral mucosa [3,4]. Additionally, catheter removal is frequently associated with discomfort or a burning sensation. For clinicians, the procedural time and ease of insertion are important factors affecting workflow efficiency and satisfaction. Despite their widespread use, conventional Foley catheters have demonstrated limited innovation in addressing these practical concerns [5].
Hydrophilic-coated catheters have been developed and used in various procedures to reduce urethral friction and patient discomfort. These catheters exhibit improved lubrication properties when hydrated, leading to easier insertion and removal, and lower mucosal trauma [5,6]. Moreover, surface coatings with antiseptic agents, such as chlorhexidine, have shown the potential for reducing bacterial colonization and preventing CAUTIs [7-9]. However, real-world clinical data comparing the effectiveness and convenience of chlorhexidine-coated hydrophilic catheters with those of conventional catheters are limited. We hypothesized that chlorhexidine-coated hydrophilic urethral catheters are superior to conventional silicone Foley catheters in terms of patient pain, procedural time, and clinician satisfaction.
This study aimed to evaluate whether the use of chlorhexidine-coated hydrophilic urethral catheters could reduce patient-reported pain, shorten procedural time, and improve clinician satisfaction compared with the use of conventional Foley catheters in short-term catheterization settings.
Ethics statement: The study protocol was approved by the Institutional Review Board (IRB) of Seoul Medical Center (IRB No: SEOUL 2022-05-007). Written informed consent was obtained from all participants before enrollment.
1. Study design
This prospective randomized controlled study was conducted in two hospitals between March 2023 and March 2025. This study was designed as a superiority trial to evaluate whether chlorhexidine-coated hydrophilic urethral catheters provide superior outcomes compared with conventional silicone Foley catheters. This study was registered at the Clinical Research Information Service (CRIS), Republic of Korea (registration No. KCT0011280; https://cris.nih.go.kr).
2. Participants and eligibility criteria
Patients aged ≥18 years who required short-term urethral catheterization for diagnostic or therapeutic purposes (e.g., perioperative management or acute urinary retention) were eligible for inclusion. The exclusion criteria included known urethral stricture, current urinary tract infection, history of urethral surgery, indwelling catheterization for >14 days, and chlorhexidine allergy.
3. Randomization and intervention
The patients were randomly assigned in a 1:1 ratio to either the control group (conventional silicone Foley catheter) or the intervention group (chlorhexidine-coated hydrophilic urethral catheter). Randomization was performed using a computer-generated random table at each hospital site. Catheterization procedures were performed by nine clinicians, four from one hospital and five from the other, all of whom were trained in the standardized protocol.
4. Description of the test device
The intervention catheter was a sterile, hydrophilic urethral catheter coated with chlorhexidine. It contained an internal water pouch that could be ruptured immediately prior to use, allowing the activation of the hydrophilic surface. This design eliminates the need for external disinfectants or lubricants, thereby simplifying the preparation process, reducing costs, minimizing the risk of external contamination, and allowing catheterization without the need for a dressing set (Supplementary Fig. 1).
5. Outcome measures
The primary endpoints were: (1) Patient-reported pain scores during catheter insertion and removal, assessed using a visual analog scale (VAS) ranging from 0 (no pain) to 10 (worst pain). (2) Procedural time, which was defined as the interval from the start of preparation to successful catheter insertion, measured in seconds using a stopwatch by the clinician performing the procedure, starting at preparation and stopping immediately after placement. (3) Clinician satisfaction score, which was rated on a scale from 0 (not satisfied) to 10 (very satisfied) immediately after the procedure.
6. Categorization of key variables
Pain scores during catheter insertion and removal were categorized as mild (VAS score, 0–3) or moderate-to-severe (VAS score, 4–10). Clinician satisfaction was stratified into low-to-moderate (0–7) and high (8–10). Procedural time was dichotomized using the median time (150 seconds) as the cutoff, classifying cases into relatively fast and slow procedures.
7. Statistical analysis
Statistical analyses were conducted using appropriate methods to compare continuous and categorical variables. Independent t-tests were used for continuous variables depending on the data distribution. Chi-square tests were used to analyze categorical outcomes. Odds ratios (ORs) were calculated for key binary outcomes. A p-value <0.05 was considered statistically significant. All analyses were performed using IBM SPSS version 28.0 (IBM Corp., Armonk, NY, USA).
A total of 140 patients were enrolled and randomized into the two groups. In the control group, two patients declined further participation, and four were excluded because of prolonged catheterization. In the intervention group, three patients were excluded because of prolonged catheterization (Fig. 1). A total of 131 patients completed the study and were included in the final analysis (control group, n=64; intervention group, n=67). Baseline characteristics, including age, indication for catheterization, and duration of catheter use, were similar between the two groups (Supplementary Table 1).
1. Patient-reported pain during catheterization
Patients who received a chlorhexidine-coated hydrophilic urethral catheter reported significantly lower pain scores during insertion and removal of the catheter than those who received a conventional silicone Foley catheter. The mean VAS pain score during insertion was 4.24±1.12 in the intervention group compared to 6.58±1.69 in the control group (p<0.01), with a mean difference of −2.34 (95% confidence interval [CI], −2.83 to −1.85). Similarly, the pain score during catheter removal was 2.76±0.68 in the intervention group and 4.45±1.31 in the control group (p<0.01), corresponding to a mean difference of −1.69 (95% CI, −2.05 to −1.33) (Table 1).
When categorized by severity, a significantly greater proportion of patients in the intervention group reported mild pain (VAS score, 0–3) during insertion (26.9%) than those in the control group (12.7%), with an OR of 2.53. Regarding removal pain, 83.6% of patients in the intervention group reported mild pain compared with 42.9% in the control group, corresponding to an OR of 6.79 (Table 2).
2. Procedural time
The time required for the procedure, defined as the duration from the start of preparation to the completion of catheter placement, was significantly shorter in the intervention group. The mean procedural time was 215.4±98.8 seconds in the intervention group and 386.0±163.6 seconds in the control group (p<0.01) (Table 1). The mean difference was −170.6 seconds (95% CI, −217.1 to −124.1), indicating a substantially shorter duration with the chlorhexidine-coated hydrophilic urethral catheter.
Using the median time (150 seconds) as a reference, the procedures were dichotomized into fast and slow categories. The intervention group demonstrated a higher proportion of fast procedures (≤150 seconds, 59.7%) than the control group (44.4%), with an OR of 1.85 (Table 2).
3. Clinician-reported satisfaction
Clinician-reported satisfaction with the procedure, measured using a 0–10 scale, was significantly higher in the intervention group. The mean satisfaction score was 8.19±1.17 in the intervention group and 3.58±1.29 in the control group (p<0.01), with a mean difference of 4.61 (95% CI, 4.19–5.03) (Table 1).
When stratified, the proportion of clinicians reporting high satisfaction (VAS score, 8–10) was 73.1% in the intervention group, which was markedly greater than 23.4% in the control group. This difference corresponded to an OR of 8.71, indicating a strong preference for chlorhexidine-coated hydrophilic urethral catheters among clinicians (Table 2).
Urethral catheterization is a routine clinical procedure that is frequently required for perioperative care, urinary retention, and diagnostic interventions. However, it often causes significant discomfort to patients and poses a risk of CAUTIs [1,2]. Many studies have focused on improving lubrication or reducing the risk of infection via catheter design changes or antiseptic coatings. However, few randomized controlled trials have investigated catheters with integrated hydrophilic and chlorhexidine coatings. Hydrophilic coated catheters are known to enhance lubrication and reduce urethral microtrauma, thus improving patient comfort in various settings, such as intermittent catheterization and urodynamic studies [5,6]. Antiseptic coatings, especially chlorhexidine, have been shown to decrease bacterial adherence and biofilm formation, significantly reducing CAUTI rates in clinical trials [8-10].
Our randomized controlled trial demonstrated that chlorhexidine-coated hydrophilic catheters significantly improved patient and clinician experience compared with conventional Foley catheters. Because this trial was designed as a superiority study, we further analyzed the effect sizes using mean differences with 95% CIs. These results consistently demonstrate the statistically and clinically significant superiority of the chlorhexidine-coated hydrophilic catheter over the conventional Foley catheter in terms of pain reduction, shorter procedural time, and higher clinician satisfaction. Specifically, pain during both insertion and removal was lower in the intervention group, with a greater proportion of patients reporting only mild pain (VAS score, 0–3). These findings indicate that the chlorhexidine-coated hydrophilic catheter effectively reduced the discomfort associated with catheterization, possibly because of both its hydrophilic surface and the antiseptic properties of chlorhexidine, which may reduce local irritation and mucosal friction. Our results are consistent with those of previous studies, such as those of Vapnek et al. [5], who showed improved comfort with hydrophilic catheters in patients with neurogenic bladder, although their work focused solely on hydrophilic coatings [5,6].
In addition to improved comfort, procedural efficiency was enhanced in the intervention group, in which a higher proportion of procedures was completed within 150 seconds. This suggests that a pre-activated hydrophilic coating combined with chlorhexidine for antiseptic effects facilitates a smoother workflow by eliminating additional lubrication or disinfection steps and reducing resistance during insertion [5,11].
Clinician satisfaction was markedly higher with the chlorhexidine-coated hydrophilic catheters. This may reflect the simplified preparation, improved handling, and reduced need for separate disinfection steps enabled by the combined hydrophilic and antiseptic catheter properties [12].
These findings represent a novel contribution to existing literature. Previous randomized controlled trials independently evaluated antimicrobial catheters, such as those coated with silver alloys or chlorhexidine, for the prevention of CAUTIs [4,11]. Other studies have assessed hydrophilic catheters for improving patient comfort [6]. However, few studies have examined these properties in a single device simultaneously. To our knowledge, this is the first randomized trial evaluating the clinical impact of a catheter that integrates both hydrophilic and antiseptic coatings in the context of short-term catheterization.
Although we did not measure CAUTI rates, one randomized trial on chlorhexidine meatal cleansing showed significant reductions in asymptomatic bacteriuria and urinary tract infection incidence over 7 days [10]. Similarly, catheters coated with noble metals, such as gold or silver alloys, have exhibited bacteriuria reductions in short-term catheterization, although the data remain heterogeneous [13]. Recent meta-analyses further support the effectiveness of antiseptic-impregnated urinary catheters in reducing CAUTIs in various clinical settings [12,13]. These studies support the theoretical rationale that chlorhexidine coatings confer microbiological advantages for short-term use.
The strengths of our study include its randomized design, objective and subjective endpoints (pain, time, and satisfaction), and multicenter setting, which enhanced external validity. Moreover, our study included an evaluation of clinician satisfaction, which has often been underreported in prior studies. This study had several limitations. Infection outcomes were not measured, limiting conclusions regarding CAUTI prevention. Clinicians were not blinded, which may have introduced bias, although the outcome measures were patient-reported or objective. Generalizability may be limited to short-term catheterization and may not extend to long-term catheterization. Future research should include infection rates and potential benefits in patients undergoing long-term catheterization, such as those with spinal cord injuries or chronic urinary retention.
In conclusion, our findings suggest that chlorhexidine-coated hydrophilic urethral catheters offer significant advantages over conventional catheters in terms of patient comfort, procedural efficiency, and clinician satisfaction. These results support wider clinical implementation, particularly in settings where short-term catheterization is frequently performed. Further research is warranted to evaluate the long-term impact on infection prevention.
Supplementary Fig. 1 and Supplementary Table 1 can be found at https://doi.org/10.12701/jyms.2025.42.68.
Supplementary Fig. 1.
Chlorhexidine-coated hydrophilic urethral catheter and schematic diagram of its layered structure. (A) Actual product image of the chlorhexidine-coated hydrophilic urethral catheter with an internal water pouch for hydrophilic activation prior to use. (B) Schematic cross-sectional diagram illustrating the catheter lumen, chlorhexidine coating layer, and hydrophilic lubricating layer.
jyms-2025-42-68-Supplementary-Fig-1.pdf
Supplementary Table 1.
Baseline characteristics of patients in the control and intervention groups
jyms-2025-42-68-Supplementary-Table-1.pdf

Conflicts of interest

No potential conflict of interest relevant to this article was reported.

Funding

This study was supported by a research grant from the Leejung Trading Co., Ltd.

Author contributions

Conceptualization, Formal analysis, Methodology, Investigation, Supervision: SKC, DGL; Data curation: SKC, JC; Funding acquisition, Validation: SKC; Writing-original draft: SKC; Writing-review & editing: all authors.

Fig. 1.
Consolidated Standards of Reporting Trials (CONSORT) flow diagram.
jyms-2025-42-68f1.jpg
Table 1.
Comparison of continuous outcome variables between the control and intervention groups
Variable Control group (n=64) Intervention group (n=67) p-value
Insertion pain (VAS) 6.58±1.69 4.24±1.12 <0.01
Removal pain (VAS) 4.45±1.31 2.76±0.68 <0.01
Procedural time (sec) 386.00±163.60 215.40±98.80 <0.01
Clinician satisfaction (VAS) 3.58±1.29 8.19±1.17 <0.01

Values are presented as mean±standard deviation.

VAS, visual analog scale.

Table 2.
Comparison of categorical outcomes between the control and intervention groups
Variable Odds ratio (95% CI) Intervention group (%) Control group (%)
Mild insertion pain 2.53 (1.01–6.32) 26.9 12.7
Mild removal pain 6.79 (3.00–15.36) 83.6 42.9
Procedural time ≤150 sec 1.85 (0.92–3.72) 59.7 44.4
Clinician satisfaction 8.71 (3.94–19.24) 73.1 23.4

Mild pain was defined as a visual analog scale score of 0–3. Procedural time was dichotomized based on a 150-second (median time) cutoff. Clinician satisfaction was considered high if the score was between 8 and 10. Odds ratios and 95% confidence intervals (CIs) are reported for chlorhexidine relative to the control.

  • 1. Saint S, Lipsky BA, Goold SD. Indwelling urinary catheters: a one-point restraint? Ann Intern Med 2002;137:125–7.ArticlePubMedPDF
  • 2. Stickler DJ. Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done. J Intern Med 2014;276:120–9.ArticlePubMedPDF
  • 3. Trautner BW, Darouiche RO. Role of biofilm in catheter-associated urinary tract infection. Am J Infect Control 2004;32:177–83.ArticlePubMedPMC
  • 4. Pickard R, Lam T, MacLennan G, Starr K, Kilonzo M, McPherson G, et al. Antimicrobial catheters for reduction of symptomatic urinary tract infection in adults requiring short-term catheterisation in hospital: a multicentre randomised controlled trial. Lancet 2012;380:1927–35.ArticlePubMed
  • 5. Vapnek JM, Maynard FM, Kim J. A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization. J Urol 2003;169:994–8.ArticlePubMed
  • 6. Liao X, Liu Y, Liang S, Li K. Effects of hydrophilic coated catheters on urethral trauma, microtrauma and adverse events with intermittent catheterization in patients with bladder dysfunction: a systematic review and meta-analysis. Int Urol Nephrol 2022;54:1461–70.ArticlePubMedPMCPDF
  • 7. Darouiche RO, Hampel OZ, Boone TB, Raad II. Antimicrobial activity and durability of a novel antimicrobial-impregnated bladder catheter. Int J Antimicrob Agents 1997;8:243–7.ArticlePubMed
  • 8. Fasugba O, Cheng AC, Gregory V, Graves N, Koerner J, Collignon P, et al. Chlorhexidine for meatal cleaning in reducing catheter-associated urinary tract infections: a multicentre stepped-wedge randomised controlled trial. Lancet Infect Dis 2019;19:611–9.Article
  • 9. Tenke P, Riedl CR, Jones GL, Williams GJ, Stickler D, Nagy E, et al. Bacterial biofilm formation on urologic devices and heparin coating as preventive strategy. Int J Antimicrob Agents 2004;(23 Suppl 1):S67–74.ArticlePubMed
  • 10. Lo E, Nicolle LE, Coffin SE, Gould C, Maragakis LL, Meddings J, et al. Strategies to prevent catheter-associated urinary tract infections in acute care hospitals: 2014 update. Infect Control Hosp Epidemiol 2014;35:464–79.ArticlePubMed
  • 11. Sun Y, Ren P, Long X. Role of noble metal-coated catheters for short-term urinary catheterization of adults: a meta-analysis. PLoS One 2020;15:e0233215. ArticlePubMedPMC
  • 12. Drekonja DM, Kuskowski MA, Wilt TJ, et al. Antimicrobial urinary catheters: a systematic review. Expert Rev Med Devices 2008;5:495–506.ArticlePubMed
  • 13. Lam TB, Omar MI, Fisher E, et al. Types of indwelling urethral catheters for short-term catheterisation in hospitalised adults. Cochrane Database Syst Rev 2014;9:CD004013.ArticlePubMedPMC

Figure & Data

References

    Citations

    Citations to this article as recorded by  
    • Polymicrobial biofilms and catheter-associated UTIs: Emerging clinical challenges and management perspectives
      Mumuksha Yadav, Awanish Kumar, Sharda Bharti
      Next Nanotechnology.2026; 10: 100679.     CrossRef

    Figure
    • 0
    Improved patient comfort and procedural efficiency using chlorhexidine-coated hydrophilic urethral catheters: a randomized controlled trial
    Image
    Fig. 1. Consolidated Standards of Reporting Trials (CONSORT) flow diagram.
    Improved patient comfort and procedural efficiency using chlorhexidine-coated hydrophilic urethral catheters: a randomized controlled trial
    Variable Control group (n=64) Intervention group (n=67) p-value
    Insertion pain (VAS) 6.58±1.69 4.24±1.12 <0.01
    Removal pain (VAS) 4.45±1.31 2.76±0.68 <0.01
    Procedural time (sec) 386.00±163.60 215.40±98.80 <0.01
    Clinician satisfaction (VAS) 3.58±1.29 8.19±1.17 <0.01
    Variable Odds ratio (95% CI) Intervention group (%) Control group (%)
    Mild insertion pain 2.53 (1.01–6.32) 26.9 12.7
    Mild removal pain 6.79 (3.00–15.36) 83.6 42.9
    Procedural time ≤150 sec 1.85 (0.92–3.72) 59.7 44.4
    Clinician satisfaction 8.71 (3.94–19.24) 73.1 23.4
    Table 1. Comparison of continuous outcome variables between the control and intervention groups

    Values are presented as mean±standard deviation.

    VAS, visual analog scale.

    Table 2. Comparison of categorical outcomes between the control and intervention groups

    Mild pain was defined as a visual analog scale score of 0–3. Procedural time was dichotomized based on a 150-second (median time) cutoff. Clinician satisfaction was considered high if the score was between 8 and 10. Odds ratios and 95% confidence intervals (CIs) are reported for chlorhexidine relative to the control.


    JYMS : Journal of Yeungnam Medical Science
    TOP