Skip Navigation
Skip to contents

JYMS : Journal of Yeungnam Medical Science

Indexed in: ESCI, Scopus, PubMed,
PubMed Central, Embase, CAS, KCI
FREE article processing charge
OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > J Yeungnam Med Sci > Volume 43; 2026 > Article
Image vignette
Angiographic ambiguity resolved by intravascular ultrasound: acute distal filling defects after balloon angioplasty for in-stent restenosis
Byeng-Ju Son1orcid, Hong-Ju Kim1orcid, Jun-Chang Jeong2orcid, Sun-Oh Kim2orcid
Journal of Yeungnam Medical Science 2026;43:73.
DOI: https://doi.org/10.12701/jyms.2026.43.73
Published online: October 30, 2026

1Division of Cardiology, Department of Internal Medicine, Dongkang Medical Center, Ulsan, Korea

2Division of Cardiology, Department of Internal Medicine, Yeungnam University Medical Center, Daegu, Korea

Corresponding author: Byeng-Ju Son, MD Division of Cardiology, Department of Internal Medicine, Dongkang Medical Center, 239 Taehwa-ro, Jung-gu, Ulsan 44455, Korea Tel: +82-52-241-1226 • E-mail: sharnhoste@naver.com
• Received: September 16, 2026   • Revised: October 25, 2026   • Accepted: October 28, 2026

© 2026 Yeungnam University College of Medicine, Yeungnam University Institute of Medical Science

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 456 Views
  • 18 Download
A 70-year-old man with heart failure with reduced ejection fraction (left ventricular ejection fraction, 36%), type 2 diabetes mellitus, and chronic kidney disease underwent percutaneous coronary intervention for unstable angina, with a polymer-free biolimus A9–coated stent (BioFreedom 4.0×24 mm; Biosensors International, Singapore) implanted from the ostium to the proximal right coronary artery (RCA). He discontinued aspirin without medical advice after 1 month and continued clopidogrel monotherapy. Two months after the index procedure, the patient presented with recurrent chest pain. Coronary angiography demonstrated in-stent restenosis of the proximal RCA with a minimal lumen area of 2.59 mm² on intravascular ultrasound (IVUS), whereas the distal vessel had a patent lumen without preexisting intraluminal material (Fig. 1A).
Lesion preparation was performed with a cutting balloon, followed by high-pressure dilation using a noncompliant balloon. Immediately after balloon deflation, angiography revealed multiple new, hazy globular filling defects in the distal RCA (Fig. 1B, Supplementary Video 1), accompanied by transient ventricular arrhythmia and worsening chest pain. The angiographic appearance alone did not allow for differentiation between superimposed thrombus, spasm, dissection, and distal embolization of the neointimal or plaque material.
IVUS of the distal RCA showed newly developed intraluminal echogenic material, producing luminal compromise in segments without a preexisting intraluminal filling defect (Fig. 1B, Supplementary Video 2). This confirmed the presence of a true intraluminal filling defect rather than a spasm or angiographic artifact, delineated its extent, and supported aspiration rather than further balloon dilation or stenting.
Manual aspiration with a 6-French aspiration catheter (Thrombuster; Kaneka, Osaka, Japan; Fig. 2A) retrieved pale, soft debris (Fig. 2A, inset) and resulted in complete angiographic resolution with the restoration of brisk distal flow (Fig. 2B). The proximal in-stent restenotic lesion was then treated with a paclitaxel-coated balloon (SeQuent Please NEO 3.5×30 mm; B. Braun, Melsungen, Germany). Symptoms and hemodynamic status stabilized, and the patient was discharged on reinstated dual antiplatelet therapy.
No-reflow phenomenon after drug-coated balloon treatment of coronary in-stent restenosis has been reported previously [1,2], with distal neointimal embolization implicated in one case [2]. In contrast, our patient developed discrete macroscopic distal filling defects during lesion preparation before drug-coated balloon treatment, while epicardial flow remained preserved. A comparison with a baseline distal IVUS pullback obtained minutes earlier demonstrated newly developed intraluminal material, prompting targeted aspiration rather than empirical no-reflow treatment.
Histopathological examination was not performed, and the composition of the retrieved material, whether neointimal or plaque-derived debris, thrombotic material, or a mixture of both, could not be determined. Because aspirin had been discontinued 1 month after the index percutaneous coronary intervention, a superimposed thrombotic component remained in the differential diagnosis. However, the message of this vignette concerns the diagnostic pathway rather than the underlying mechanism. Intraluminal filling defects and angiographically hazy lesions are among the situations where intracoronary imaging is explicitly recommended to clarify an ambiguous angiogram [3]. IVUS converted an uninterpretable angiogram into an actionable finding within minutes and allowed the bailout to be chosen from imaging results rather than inference.
Supplementary Videos 1 and 2 can be found via https://doi.org/10.12701/jyms.2026.43.73.
Supplementary Video 1.
Supplementary Video 2.

Ethics statement

Written informed consent for the publication of this report and accompanying images was obtained from the patient. Institutional Review Board approval was waived for this single-patient image vignette in accordance with institutional policy. All identifying information has been removed.

Conflicts of interest

No potential conflict of interest relevant to this article was reported.

Funding

None.

Use of artificial intelligence

Claude (Anthropic) assisted with language and manuscript editing. The authors reviewed and edited the content as needed and take full responsibility for the final manuscript.

Author contributions

Conceptualization: BJS; Data curation: BJS, HJK, JCJ; Investigation: BJS, JCJ; Visualization: HJK, SOK; Writing-original draft: BJS; Writing-review & editing: all authors.

Fig. 1.
(A) Baseline coronary angiography shows in-stent restenosis at the proximal right coronary artery. Red dotted lines mark the levels of the corresponding intravascular ultrasound cross-sections, obtained from separate pullbacks of the proximal (P1–P3) and distal (D1–D3) segments. P1 to P3 show marked neointimal thickening within the stented proximal segment, whereas D1 to D3 show a patent distal lumen without preexisting intraluminal material or significant luminal narrowing. (B) Coronary angiography immediately after noncompliant balloon deflation shows new, hazy globular filling defects in the distal right coronary artery; the white dashed bracket delineates the affected segment and the red dotted lines mark the levels of the cross-sections numbered 1 to 6, which span the territory covered by D1 to D3. Newly developed intraluminal echogenic material is present at positions 2 to 5 (red arrow in position 2; red dotted outlines in positions 3 to 5, where the material fills most of the lumen), causing luminal compromise in a segment that had shown no preexisting intraluminal material at baseline.
jyms-2026-43-73f1.jpg
Fig. 2.
(A) A 6-French aspiration catheter advanced into the distal right coronary artery; white arrowheads indicate the location of the filling defects before aspiration. Inset: gross photograph of the pale, soft debris retained within the filter mesh of the aspiration system. (B) Coronary angiography after manual aspiration shows complete resolution of the distal filling defects and restoration of brisk distal flow.
jyms-2026-43-73f2.jpg
  • 1. Chung HH, Moon KW, Jung MH, Yang HK, Park KS, Yoo KD. No-reflow phenomenon during treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. Korean Circ J 2012;42:431–3.ArticlePubMedPMC
  • 2. Kim SE, Choi KH, Song YB. An unusual no-reflow phenomenon due to neointimal tissue embolization during drug eluting balloon intervention in stent restenosis: a case report. Catheter Cardiovasc Interv 2023;102:481–5.ArticlePubMed
  • 3. Saito Y, Kobayashi Y, Fujii K, Sonoda S, Tsujita K, Hibi K, et al. CVIT 2025 clinical expert consensus document on intravascular ultrasound. Cardiovasc Interv Ther 2025;40:211–25.ArticlePubMedPMCPDF

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      Figure
      • 0
      • 1
      Angiographic ambiguity resolved by intravascular ultrasound: acute distal filling defects after balloon angioplasty for in-stent restenosis
      Image Image
      Fig. 1. (A) Baseline coronary angiography shows in-stent restenosis at the proximal right coronary artery. Red dotted lines mark the levels of the corresponding intravascular ultrasound cross-sections, obtained from separate pullbacks of the proximal (P1–P3) and distal (D1–D3) segments. P1 to P3 show marked neointimal thickening within the stented proximal segment, whereas D1 to D3 show a patent distal lumen without preexisting intraluminal material or significant luminal narrowing. (B) Coronary angiography immediately after noncompliant balloon deflation shows new, hazy globular filling defects in the distal right coronary artery; the white dashed bracket delineates the affected segment and the red dotted lines mark the levels of the cross-sections numbered 1 to 6, which span the territory covered by D1 to D3. Newly developed intraluminal echogenic material is present at positions 2 to 5 (red arrow in position 2; red dotted outlines in positions 3 to 5, where the material fills most of the lumen), causing luminal compromise in a segment that had shown no preexisting intraluminal material at baseline.
      Fig. 2. (A) A 6-French aspiration catheter advanced into the distal right coronary artery; white arrowheads indicate the location of the filling defects before aspiration. Inset: gross photograph of the pale, soft debris retained within the filter mesh of the aspiration system. (B) Coronary angiography after manual aspiration shows complete resolution of the distal filling defects and restoration of brisk distal flow.
      Angiographic ambiguity resolved by intravascular ultrasound: acute distal filling defects after balloon angioplasty for in-stent restenosis

      JYMS : Journal of Yeungnam Medical Science
      TOP