Skip Navigation
Skip to contents

JYMS : Journal of Yeungnam Medical Science

Indexed in: ESCI, Scopus, PubMed,
PubMed Central, CAS, DOAJ, KCI
FREE article processing charge
OPEN ACCESS
SEARCH
Search

Author index

Page Path
HOME > Browse Articles > Author index
Search
Gu Ru Hong 2 Articles
Treatment of Coronary Artery Perforation and Tamponade Complicating Balloon Angioplasty by PTFE-Covered Stent. A Case Report.
Jong Seon Park, Gu Ru Hong, Jun Ho Bae, Ihn Ho Cho, Bong Sup Shim, Young Jo Kim, Dong Gu Shin
Yeungnam Univ J Med. 2005;22(1):90-95.   Published online June 30, 2005
DOI: https://doi.org/10.12701/yujm.2005.22.1.90
  • 1,473 View
  • 5 Download
AbstractAbstract PDF
A coronary artery perforation is a rare but often fatal complication of angioplasty. We experienced a coronary artery perforation and cardiac tamponade during balloon angioplasty. A polytetrafluorethylene (PTFE) -covered stent was used to successfully close the perforation.
Change of Serum Levels of C-Reactive Protein After Coronary Angioplasty and Its Effects on Clinical Restenosis.
Jong Seon Park, Gu Ru Hong, Chae Hoon Lee, Dong Gu Shin, Young Jo Kim, Bong Sup Shim
Yeungnam Univ J Med. 2001;18(2):215-225.   Published online December 31, 2001
DOI: https://doi.org/10.12701/yujm.2001.18.2.215
  • 1,554 View
  • 0 Download
AbstractAbstract PDF
BACKGROUND
There are many evidences that inflammation is an important determinant of the development of atherosclerosis and one of the systemic markers of inflammation, C-reactive protein(CRP), is associated with extent of coronary artery disease and risk of coronary events. We assessed the time response of CRP response after coronary angioplasty and it's influence on the clinical restenosis in angina patients. MATERIALS AND METHODS: Patients included 36 angina patients undergoing single vessel angioplasty. Levels of CRP were measured before and 12, 24, 48, and 72 hours after angioplasty. Clinical restenosis was assessed at 6 months after procedure. RESULTS: Baseline CRP level was 0.30+/-0.01 mg/dL in stable and 0.46+/-0.28 mg/dL in unstable angina patients(p<0.05). After angioplasty, CRP level was increased with peak at 24 hour and persisted to 72 hours after angioplasty. At 24 hour after angioplasty, the magnitude of CRP change was 0.32+/-0.31 mg/dL in stable and 0.79+/-0.73 mg/dL in unstable angina patient(p<0.05). The change of CRP level was not associated with troponin-T after angioplasty. In unstable angina patients, clinical restenosis was developed in 8% of patients with low baseline CRP levels and in 50% of those with high baseline CRP levels more than 0.6 mg/dL(p<0.05). CONCLUSION: In unstable angina patients, inflammatory response is more increased than stable angina patients, and increased inflammatory response effects on the restenosis after coronary angioplasty.

JYMS : Journal of Yeungnam Medical Science
TOP