Skip Navigation
Skip to contents

JYMS : Journal of Yeungnam Medical Science

Indexed in: ESCI, Scopus, PubMed,
PubMed Central, CAS, DOAJ, KCI
FREE article processing charge
OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
2 "Tl-201"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients.
Kyung Ah Chun, Ihn Ho Cho, Kyu Chang Won, Kyung Hee Lee, Hyung Woo Lee, Myung Soo Hyun, Jae Tae Lee, Kyu Bo Lee
Yeungnam Univ J Med. 2002;19(2):107-115.   Published online December 31, 2002
DOI: https://doi.org/10.12701/yujm.2002.19.2.107
  • 1,598 View
  • 3 Download
AbstractAbstract PDF
PURPOSE: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. MATERIALS AND METHODS: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. RESULTS: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. CONCLUSION: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.
Dual-Isotope SPECT Imaging with Thallium-201 and Technetium-99m MIBI in Detecting Coronary Artery Disease.
Gyu Gwang Lee, Ihn Ho Cho, Hyoung Woo Lee, Jong Sun Park, Kyu Chang Won, Dong Gu Sin, Young Jo Kim, Bong Sup Shim
Yeungnam Univ J Med. 1999;16(1):101-107.   Published online June 30, 1999
DOI: https://doi.org/10.12701/yujm.1999.16.1.101
  • 1,530 View
  • 0 Download
AbstractAbstract PDF
We evaluated the results of sequential SPECT dual-isotope imaging with Tl-201 and Tc-99m MIBI in 24 patients, all of whom also had coronary angiography within the past one month. Coronary angiography showed that 12 patients had no CAD, 4 patients had one-vessel CAD, 7 patients had two-vessel CAD and 1 patient had three-vessel CAD. Serial studies of resting Tl-201 and dipyridamole stress Tc-99m MIBI were completed within 2 hours. When more then 50% of coronary artery narrowing was considered significant. The overall sensitivity and specification of CAD detection were 91.7%. The sensitivity of CAD detection in patients with one-vessel and multi-vessel diseases was 75% and 100%, respectively. Therefore, sequential dual-isotope SPECT demonstrated high sensitivity and specificity of CAD detection. In conclusion, sequential dual-isotope imaging is feasible and can be completed in a short time and may therefore enhance laboratory throughput and patient convenience.